Troubleshooting Guide: Ensure that all instructions in the program are used correctly. Below are some common syntax errors encountered in Mitsubishi FX series PLCs:

Error Number (D8065): 6503
Error Message: SYNTAX ERROR (PLC stops running, grammar error)
Error Content: The instruction "OUTT" is used without a set value after "OUTC", leading to an insufficient number of operands.
Countermeasure: Review and verify the correct usage of each instruction in your program.

Error Number (D8065): 6504
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: The P-number is used multiple times, or there's an interruption in the input number and repeated use of high-speed counter input numbers.
Countermeasure: Double-check the proper assignment and usage of P-numbers and high-speed counter inputs.

Error Number (D8065): 6505
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: A specified component is out of range.
Countermeasure: Confirm that all components referenced in the program are within valid limits.

Error Number (D8065): 6506
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: An undefined instruction was used.
Countermeasure: Make sure all instructions used are supported by your PLC model.

Error Number (D8065): 6507
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: There is an error in the P-number configuration.
Countermeasure: Check the correct application of P-numbers in your code.

Error Number (D8065): 6508
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: I-number is invalid or incorrectly assigned.
Countermeasure: Verify that all I-numbers used in the program are properly defined.

Error Number (D8065): 6509
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: General syntax issue with no specific cause identified.
Countermeasure: Perform a full review of your program for any inconsistencies or incorrect syntax.

Error Number (D8065): 6510
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: Improper use of N-number in MC/MCR instructions.
Countermeasure: Ensure that the N-number is correctly applied in all MC/MCR blocks.

Error Number (D8065): 6511
Error Message: SYNTAX ERROR (PLC stopped running, grammar error)
Error Content: Repeated use of input numbers and high-speed counter input numbers during insertion.
Countermeasure: Avoid overlapping or duplicate assignments in input and high-speed counter configurations.

Always ensure that your PLC program follows the syntax rules specific to your model. If the problem persists, consider using a simulator or consulting the official documentation for further guidance.