Determination of salinity in paste sauce or juice-like compound seasoning - Database & Sql Blog Articles

WIFI test head can be customized for other specifications
Test - lowercase jpg
Kaixin micro test

[Foreword]

The concentrated chicken juice series products are increasingly recognized by consumers, and the trend of selling sauces and paste-like compound seasonings continues to grow. This indicates that juice, sauce, and paste-based compound seasonings are becoming a major direction in the development of seasoning products. By analyzing conductivity and salinity data, we were able to obtain accurate results for the salinity of the paste, and the finished product was fully tested.

Chicken cream detection method,

Conductivity method,

Standard curve line,

Test methods

(Ai Tuo) ES-421

Conductivity salinity meter

ATAGO

[Physical and Chemical Test]

Concentrated chicken juice mixing process

Sample: Spicy space

Chicken paste salinity test

Date of inspection: 2015 year 7 month 7 day

Use the instrument: ATAGO (Ai Tuo) ES-421 Conductivity salinity meter

Test Methods:

Weighing chicken paste 5g, add water 45g, dilute, and measure the sample with the instrument.

Measuring salinity value 1.07, because it is diluted 10 times, so the original chicken paste salinity value is 10.7%.

If paste or juice-like compound seasonings exceed the measurement range of 10%, dilution is necessary. For example, if the salt content is 12%, diluting it 10 times will result in 1.2‰, and after diluting 5 times, it becomes 6‰.

To ensure the measurement falls within the acceptable range, always perform a dilution treatment first.

When there is a large amount of oil in the sample, it can still be measured. However, for samples like ramen soup with floating grease, the measured value may be unstable. After allowing the sample to settle, using a chopstick to check can provide a more stable reading. When measuring salt content in oily or salted foods, avoid collecting oil and instead add water for dilution.

After dilution, mix well. The displayed value multiplied by 10 gives the original salinity value of the sample.



Dilution method

ES-421 Conductivity salinity meter

This method can also be applied to solid samples such as dried fish, bacon, high-oil products, and sauces. If you need more information about the product or would like to have samples tested, please contact the ATAGO China Branch. We’ll be happy to assist you.

ATAGO (Ai Tuo) China Marketing Department (Xuan)

FPV Drone

FPV Drone TrueX Frame Overview
Mark4 V2 Mark4 7inch 295mm / 8inch 367mm / 9inch 387mm / 10inch 427mm 3K Full Carbon Fiber TrueX Frame for FPV Camera Kit Done:
FPV drone frame 4FPV drone frame 2FPV drone frame 3

Carbon Fiber FPV Drone Frame,FPV Drone TrueX Frame,Carbon Fiber FPV Frame

Jiangsu Yunbo Intelligent Technology Co., Ltd , https://www.fmodel-ai.com

This entry was posted in on